APC Smart-UPS RT 1500VA RM 110V
For at se vore priser skal du være oprettet som kunde: Er du allerede oprettet som kunde skal du logge ind.
|
APC Smart-UPS RT 1500VA RM 110V
-
Effekt
1.5kVA
-
Produkt
Eksterne UPS
|
Beskrivelse
Specifikationer
Tilbehør
APC SMART-UPS RT 1500VA 120V
SURTA1500XL
APC Smart-UPS RT, 1500VA/1050W, Input 120V/Output 120V, Interface Port DB-9 RS-232, Smart-Slot, USB, Extended runtime model, Rack Height 2 U
Includes: CD with software, Documentation CD, Installation Guide, Smart UPS signalling RS-232 cable, USB cable, User Manual
Features
Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS overload condition or fault.
Scalable runtime
Allows additional run time to be quickly added as needed.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
Network manageable
Monitor and control the UPS and access environmental information remotely via included PowerChute software or APC's Network Management Card with temperature monitoring (included in all models above 3kVA).
InfraStruXure Manager compatible
Enables centralized management via APC's InfraStruXure Manager.
SmartSlot
Customize UPS capabilities with management cards.
LED status indicators
Enables quick understanding and response to visual indicators showing UPS status.
Serial Connectivity
Provides management of the UPS via a serial port.
Plug-and-Play external batteries
Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
Rack/Tower convertible
Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
Flash-upgradeable firmware
Easy implementation of new firmware upgrades.
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Predictive failure notification
Provides early-warning fault analysis ensuring proactive component replacement.
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Audible alarms
Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition.
Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
Generator compatible
Ensures clean, uninterrupted power to the loads in the event of an extended power outage
Cold-start capable
Provides temporary battery power when the utility power is out.
Resettable circuit breakers
Enables quick recovery from UPS overload events.
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. UL, FCC, CE, C-Tick approvals.
Output
Output Power Capacity
1050 Watts / 1500 VA
Max Configurable Power
1050 Watts / 1500 VA
Nominal Output Voltage
120V
Efficiency at Full Load
90%
Output Voltage Distortion
Less than 3%
Output Frequency (sync to mains)
50/60 Hz +/- 3 Hz user adjustable +/- 0.1
Input
Nominal Input Voltage
120V
Input Frequency
50/60 Hz +/- 5 Hz (auto sensing)
Cord Length
6 feet ( 1.83 meters)
Input voltage range for main operations
90 - 150V
Batteries & Runtime
Battery Type
Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
Included Battery Modules
1
Typical recharge time
3 hour(s)
Replacement battery cartridge
RBC57,
SURTA48XLBP,
SURTA48RMXLBP
Typical Backup Time
at Half Load
22.2 minutes (525 Watts)
Typical Backup Time
at Full Load
8.6 minutes (1050 Watts)
Runtime Chart
Smart-UPS RT
Extended Run Options
APC SMART-UPS RT 1500VA 120V
Communications & Management
Interface Port(s)
DB-9 RS-232,Smart-Slot,USB
Available SmartSlot™ Interface Quantity
1
Control panel
LED status display with load and battery bar-graphs and On Line : On Battery : Replace Battery : Overload and Bypass Indicators
Audible Alarm
Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm
Emergency Power Off (EPO)
Yes
Surge Protection and Filtering
Surge energy rating
540 Joules
Physical
Maximum Height
17.00 inches (432 mm)
Maximum Width
3.35 inches ( 85 mm)
Maximum depth
22.00 inches (559 mm)
Net Weight
60.50 lbs. ( 27.50 kg)
Shipping Weight
69.00 lbs. ( 31.36 kg)
Shipping Height
10.25 inches (260 mm)
Shipping Width
24.00 inches (610 mm)
Shipping Depth
29.00 inches (737 mm)
Environmental
Operating Environment
32 - 104 °F (0 - 40 °C)
Operating Relative Humidity
0 - 95%
Operating Elevation
0-10000 feet (0-3000 meters)
Storage Temperature
-4 - 122 °F (-20 - 50 °C)
Storage Relative Humidity
0 - 95%
Storage Elevation
0-50000 feet (0-15000 meters)
Audible noise at 1 meter from surface of unit
45 dBA
Online Thermal Dissipation
393 BTU/hr
Conformance
Regulatory Approvals
BSMI,CSA,FCC Part 15 Class B,UL 1778
Standard Warranty
2 years repair or replace
Output strømkapacitet (VA) | 1,5 kVA |
Udgangseffekt | 1050 W |
Indgangsfrekvens | 50/60 Hz |
Overspænding energivurdering | 540 J |
Nødstrøm Off (EPO) | Ja |
Støjniveau | 45 dB |
Lydalarmer | Ja |
Batteriteknologi | Blybatterier (VRLA) |
Typisk backup tid ved fuld styrke | 8,6 min. |
Typisk backup tid ved halv styrke | 22,2 min. |
Opladningstid for batteri | 3 t |
Hot-swap batteri | Ja |
Produktfarve | Sort |
Kabellængde | 1,83 m |
LED-indikatorer | Ja |
Certificering | BSMI,CSA,FCC Part 15 Class B,UL 1778 |
Driftstemperatur (T-T) | 0 - 40 °C |
Opbevaringstemperatur (T-T) | -20 - 50 °C |
Relativ luftfugtighed ved drift (H-H) | 0 - 95% |
Relativ luftfugtighed ved opbevaring (H-H) | 0 - 95% |
Driftshøjde | 0 - 3000 m |
Ikke-drift højde | 0 - 15000 m |
Vægt | 27,5 kg |
Output-forbindere | (6) NEMA 5-15R |
Input forbindertype | NEMA 5-15P |
Dimensioner (BxDxH) | 85 x 559 x 432 mm |
Nominel udgangsspænding | 120 V |
Nominel indgangsspænding | 120 V |
I/O-porte | DB-9 RS-232,Smart-Slot,USB |
Servere & Storage / Service & Support
Selvom vi gør vort bedste for at give fyldestgørende information, så er billederne kun vejledende, og selve varen er ikke nødvendigvis 100% identisk med det viste billede. Produkter kan være vist med ekstraudstyr der ikke er inkluderet eller i andre form- og farvevarianter. Hvis der er forskel mellem produktoverskrift, beskrivelse og billede, så er det produktoverskriften som gælder. Hvis du er i tvivl, så kontakt os gerne. Vi tager forbehold for trykfejl, ændring af priser og specifikationer uden varsel.